MAK Commission: Benzene - Method for the determination of benzene in workplace air using gas chromatography after solvent desorption

This analytical method is a validated measurement procedure for the determination of benzene [71-43-2] in workplace air averaged over the sampling period after personal or stationary sampling. Sampling is performed by drawing a defined volume of air through an adsorption tube filled with carbon black using a suitable flow-regulated pump. For sampling the flow rate is set to 0.33 l/min with an air sample volume of 40 l (which corresponds to a sampling period of 2 h). For analysis the sample is treated with carbon disulfide and analysed by means of GC with a mass spectrometric detector (MSD). The quantitative evaluation is based on a calibration function obtained by means of a multiple-point calibration. The relative limit of quantification (LOQ) is 4 μg/m³ benzene for an air sample volume of 40 l. The mean recovery was 100% for an evaluation with MSD and the expanded uncertainty lays between 21 and 23%.

Bibliographic information

Title:  MAK Commission: Benzene - Method for the determination of benzene in workplace air using gas chromatography after solvent desorption. Air Monitoring Method

Written by:  U. Lewin-Kretzschmar, T. H. Brock, R. Hebisch, A. Hartwig

in: The MAK Collection for Occupational Health and Safety, Vol 6, No 4, 2021.  pages: 1-8, DOI: 10.34865/am7143ae6_4or

Download file "MAK Commission: Benzene - Method for the determination of benzene in workplace air using gas chromatography after solvent desorption" (PDF, 469 KB, Not barrier-free file)

Further Publications

MAK Commission: Benzene - Method for the determination of benzene in workplace air using gas chromatography after thermal desorption

Article 2021

This analytical method is a validated measurement procedure for the determination of benzene [71-43-2] in workplace air averaged over the sampling period after personal or stationary sampling. Sampling is performed by drawing a defined volume of air through a thermal desorption tube filled with …

To the Publication